Products
New Energy Powers a Better Life.
Gas generators, CNG storage, refuelling and regulation, all built by Pulita. Download the specifications for every model.
Our products
Choose a product.
Tap a product to see its specifications. Every table can be downloaded as a PDF, and each generator and MRU model has its own PDF datasheet.
0115–2,500 kVA

CNG generator.
Pulita CNG generator sets run on compressed or pipeline natural gas for continuous 24-hour duty in hospitals, factories, estates and telecom sites. Larger plants are containerized and can be synchronised to match any load.
| Genset model | Prime powerkW / kVA | Standby powerkW / kVA | Rated voltageV | Phase | RPM | CNG consumptionm³/h | Dimensionsmm (L × W × H) | Weightkg | Datasheetper model |
|---|---|---|---|---|---|---|---|---|---|
| PLT-15GF15 kVA | 12/15 | 13.2/16.5 | 400/230 V | 3-phase | 1500 | 3.6 m³/h | 2200 × 1050 × 1400 | 950 | |
| PLT-20GF20 kVA | 16/20 | 17.6/22 | 400/230 V | 3-phase | 1500 | 4.8 m³/h | 2200 × 1050 × 1450 | 980 | |
| PLT-25GF25 kVA | 20/25 | 22/27.5 | 400/230 V | 3-phase | 1500 | 6 m³/h | 2200 × 1050 × 1450 | 1,000 | |
| PLT-30GF30 kVA | 24/30 | 26.4/33 | 400/230 V | 3-phase | 1500 | 7.2 m³/h | 2200 × 1050 × 1450 | 1,000 | |
| PLT-40GF40 kVA | 32/40 | 35.2/44 | 400/230 V | 3-phase | 1500 | 9.6 m³/h | 2400 × 1050 × 1450 | 1,050 | |
| PLT-50GF50 kVA | 40/50 | 44/55 | 400/230 V | 3-phase | 1500 | 12 m³/h | 2400 × 1050 × 1450 | 1,080 | |
| PLT-60GF60 kVA | 48/60 | 52.8/66 | 400/230 V | 3-phase | 1500 | 14.4 m³/h | 2800 × 1050 × 1650 | 1,400 | |
| PLT-80GF80 kVA | 64/80 | 70.4/88 | 400/230 V | 3-phase | 1500 | 19.2 m³/h | 2800 × 1050 × 1650 | 1,600 | |
| PLT-100GF100 kVA | 80/100 | 88/110 | 400/230 V | 3-phase | 1500 | 24 m³/h | 2800 × 1050 × 1650 | 1,640 | |
| PLT-125GF125 kVA | 100/125 | 110/137 | 400/230 V | 3-phase | 1500 | 30 m³/h | 3000 × 1250 × 1800 | 2,500 | |
| PLT-150GF150 kVA | 120/150 | 132/165 | 400/230 V | 3-phase | 1500 | 36 m³/h | 3000 × 1250 × 1800 | 2,560 | |
| PLT-187.5GF187.5 kVA | 150/187.5 | 165/206.25 | 400/230 V | 3-phase | 1500 | 45 m³/h | 3100 × 1180 × 1960 | 2,600 | |
| PLT-200GF200 kVA | 160/200 | 176/220 | 400/230 V | 3-phase | 1500 | 48 m³/h | 3300 × 1250 × 2060 | 2,800 | |
| PLT-250GF250 kVA | 200/250 | 220/275 | 400/230 V | 3-phase | 1500 | 60 m³/h | 3600 × 1450 × 2060 | 2,900 | |
| PLT-300GF300 kVA | 240/300 | 264/330 | 400/230 V | 3-phase | 1500 | 72 m³/h | 3800 × 1550 × 2160 | 3,200 | |
| PLT-350GF350 kVA | 280/350 | 308/385 | 400/230 V | 3-phase | 1500 | 84 m³/h | 3800 × 1550 × 2160 | 3,380 | |
| PLT-500GF500 kVA | 400/500 | 440/550 | 400/230 V | 3-phase | 1500 | 116 m³/h | 4000 × 1550 × 2260 | 4,400 | |
| PLT-625GF625 kVA | 500/625 | 550/687.5 | 400/230 V | 3-phase | 1500 | 139.2 m³/h | 20 ft container | 10,500 | |
| PLT-800GF800 kVA | 640/800 | 704/888 | 400/230 V | 3-phase | 1500 | 185.6 m³/h | 20 ft container | 11,000 | |
| PLT-1000GF1,000 kVA | 800/1000 | 880/1100 | 400/230 V | 3-phase | 1500 | 224 m³/h | 20 ft container | 11,000 | |
| PLT-1250GF1,250 kVA | 1000/1250 | 1100/1375 | 400/230 V | 3-phase | 1500 | 280 m³/h | 40 ft container | 16,000 | |
| PLT-1800GF1,800 kVA | 1440/1800 | 1584/1980 | 400/230 V | 3-phase | 1500 | 403.2 m³/h | 40 ft container | 17,100 | |
| PLT-2500GF2,500 kVA | 2000/2500 | 2200/2750 | 400/230 V | 3-phase | 1000 | 560 m³/h | Customised container | 35,000 |
Click PDF for each model’s datasheet.
Remark: The technical parameters above are for reference only. Actual data may vary depending on specific production conditions.
0215–300 kVA

LPG generator.
LPG generator sets for sites without natural gas. They run from cylinders or a bulk tank, start with one button and cut fuel costs sharply compared with diesel. LPG generator sets can be configured for dual-fuel (LPG/CNG) operation based on customer requirements.
| Genset model | Prime powerkW / kVA | Standby powerkW / kVA | Rated voltageV | Phase | RPM | LPG consumptionkg/h | Dimensionsmm (L × W × H) | Weightkg | Datasheetper model |
|---|---|---|---|---|---|---|---|---|---|
| PLT-15GF15 kVA | 12/15 | 13.2/16.5 | 400/230 V | 3-phase | 1500 | 3 kg/h | 2200 × 1050 × 1400 | 950 | |
| PLT-20GF20 kVA | 16/20 | 17.6/22 | 400/230 V | 3-phase | 1500 | 4 kg/h | 2200 × 1050 × 1450 | 980 | |
| PLT-25GF25 kVA | 20/25 | 22/27.5 | 400/230 V | 3-phase | 1500 | 5 kg/h | 2200 × 1050 × 1450 | 1,000 | |
| PLT-30GF30 kVA | 24/30 | 26.4/33 | 400/230 V | 3-phase | 1500 | 6 kg/h | 2200 × 1050 × 1450 | 1,000 | |
| PLT-40GF40 kVA | 32/40 | 35.2/44 | 400/230 V | 3-phase | 1500 | 8 kg/h | 2400 × 1050 × 1450 | 1,050 | |
| PLT-50GF50 kVA | 40/50 | 44/55 | 400/230 V | 3-phase | 1500 | 10 kg/h | 2400 × 1050 × 1450 | 1,080 | |
| PLT-60GF60 kVA | 48/60 | 52.8/66 | 400/230 V | 3-phase | 1500 | 12 kg/h | 2800 × 1050 × 1650 | 1,400 | |
| PLT-80GF80 kVA | 64/80 | 70.4/88 | 400/230 V | 3-phase | 1500 | 16 kg/h | 2800 × 1050 × 1650 | 1,600 | |
| PLT-100GF100 kVA | 80/100 | 88/110 | 400/230 V | 3-phase | 1500 | 20 kg/h | 2800 × 1050 × 1650 | 1,640 | |
| PLT-125GF125 kVA | 100/125 | 110/137 | 400/230 V | 3-phase | 1500 | 25 kg/h | 3000 × 1250 × 1800 | 2,500 | |
| PLT-150GF150 kVA | 120/150 | 132/165 | 400/230 V | 3-phase | 1500 | 28.8 kg/h | 3100 × 1180 × 1960 | 2,560 | |
| PLT-187.5GF187.5 kVA | 150/187.5 | 165/206.25 | 400/230 V | 3-phase | 1500 | 36 kg/h | 3100 × 1180 × 1960 | 2,600 | |
| PLT-200GF200 kVA | 160/200 | 176/220 | 400/230 V | 3-phase | 1500 | 38.4 kg/h | 3300 × 1250 × 2060 | 2,800 | |
| PLT-250GF250 kVA | 200/250 | 220/275 | 400/230 V | 3-phase | 1500 | 48 kg/h | 3600 × 1450 × 2060 | 2,900 | |
| PLT-300GF300 kVA | 240/300 | 264/330 | 400/230 V | 3-phase | 1500 | 57.6 kg/h | 3800 × 1550 × 2160 | 3,200 |
Click PDF for each model’s datasheet.
Remark: The technical parameters above are for reference only. Actual data may vary depending on specific production conditions.
0315–1,250 kVA

Biogas generator.
Biogas generator sets turn gas from digesters, farms, food processing, wastewater and landfill into electricity. We configure each set to your gas analysis and pair it with gas treatment to remove H₂S and moisture.
| Genset model | Prime powerkW / kVA | Standby powerkW / kVA | Rated voltageV | Phase | RPM | Biogas consumption | Datasheetper model |
|---|---|---|---|---|---|---|---|
| PLT-15GF15 kVA | 12/15 | 13.2/16.5 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-20GF20 kVA | 16/20 | 17.6/22 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-25GF25 kVA | 20/25 | 22/27.5 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-30GF30 kVA | 24/30 | 26.4/33 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-40GF40 kVA | 32/40 | 35.2/44 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-50GF50 kVA | 40/50 | 44/55 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-60GF60 kVA | 48/60 | 52.8/66 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-80GF80 kVA | 64/80 | 70.4/88 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-100GF100 kVA | 80/100 | 88/110 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-125GF125 kVA | 100/125 | 110/137 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-150GF150 kVA | 120/150 | 132/165 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-187.5GF187.5 kVA | 150/187.5 | 165/206.25 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-200GF200 kVA | 160/200 | 176/220 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-250GF250 kVA | 200/250 | 220/275 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-300GF300 kVA | 240/300 | 264/330 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-350GF350 kVA | 280/350 | 308/385 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-500GF500 kVA | 400/500 | 440/550 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-625GF625 kVA | 500/625 | 550/687.5 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-800GF800 kVA | 640/800 | 704/888 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-1000GF1,000 kVA | 800/1000 | 880/1100 | 400/230 V | 3-phase | 1500 | Depends on methane (CH₄) content | |
| PLT-1250GF1,250 kVA | 1000/1250 | 1100/1375 | 400/230 V | 3-phase | 1000 | Depends on methane (CH₄) content |
Biogas consumption depends on the methane content of your gas: send us your gas analysis for exact figures. Click PDF for each model’s datasheet.
Remark: The technical parameters above are for reference only. Actual data may vary depending on specific production conditions.
04200–7,000 scm

CNG cascade.
Pulita assembles 150–200 L cylinders into CNG cascades for on-site gas storage. Cascades feed gas generators through a PRMS, and store gas at MRUs and daughter stations, wherever there is no pipeline.
| Storage capacity | 200–7,000 scm |
|---|---|
| Cylinders | 150–200 L cylinders assembled into cascades |
| Working pressure | 200–250 bar |
| Construction | Modular steel frame, skid-mounted |
| Use | On-site CNG storage for gas generators, MRUs and daughter stations |
| Connects to | PRMS and Pulita gas generator sets |
Remark: The technical parameters above are for reference only. Actual data may vary depending on specific production conditions.
05600–7,000 scm/h

MRU (integrated daughter station).
The MRU is a complete CNG daughter station on one skid: hydraulic compressor, gas storage, dispenser, metering, filtration and gas-leak alarms. It arrives ready to connect, needs no major civil works and can be relocated as demand grows.
| Model | Rated capacity | Output pressure | Configuration | Datasheetper model |
|---|---|---|---|---|
| MRU 600 | 600 scm/h | 250 bar | Skid-mounted, hydraulic compressor · fixed or mobile | |
| MRU 1,200 | 1,200 scm/h | 250 bar | Skid-mounted, hydraulic compressor · fixed or mobile | |
| MRU 2,500 | 2,500 scm/h | 250 bar | Skid-mounted, hydraulic compressor · fixed or mobile | |
| MRU 3,200 | 3,200 scm/h | 250 bar | Skid-mounted, hydraulic compressor · fixed or mobile | |
| MRU 4,000 | 4,000 scm/h | 250 bar | Skid-mounted, hydraulic compressor · fixed or mobile | |
| MRU 6,000 | 6,000 scm/h | 250 bar | Skid-mounted, hydraulic compressor · fixed or mobile | |
| MRU 7,000 | 7,000 scm/h | 250 bar | Skid-mounted, hydraulic compressor · fixed or mobile |
Models: 600, 1,200, 2,500, 3,200, 4,000, 6,000 and 7,000 scm/h. Click PDF for each model’s datasheet.
Remark: The technical parameters above are for reference only. Actual data may vary depending on specific production conditions.
0620–20,000 m³/h

PRMS.
The pressure regulating and metering skid (PRMS) steps high-pressure CNG or pipeline gas down to the pressure your equipment needs, heats it to prevent freezing and meters every cubic metre for accurate cost control.
| Flow range | 20 scm/h – 20,000 m³/h |
|---|---|
| Inlet | High-pressure CNG (up to 250 bar) or pipeline gas |
| Functions | Multi-stage pressure reduction, heating and flow metering |
| Safety | Safety shut-off and relief valves |
| Enclosure | Weatherproof, lockable cabinet or skid |
Remark: The technical parameters above are for reference only. Actual data may vary depending on specific production conditions.
Ready when you are
Stop burning cash on diesel.
Share your load and running hours. Our Lagos engineers will size the right generator, station or turnkey system and send a costed proposal.